![]() |
![]() |
![]() |
![]() |
![]() |
|||||||||
![]() |
deutsch
| english
| español
| 汉语
|
||||||||||||
![]() | |||||||||||||
![]() | |||||||||||||
![]() |
![]() |
||||||||||||
![]() | |||||||||||||
|
|
Water Mist HistoryFOGTEC Water MistFOGTEC Brandschutz GmbH & Co. KG was founded in 1997 and unites the water mist businesses of KAMAT, a leading manufacturer of high pressure water systems, brought to FOGTEC its unique know-how and is today still a partner of FOGTEC. The history of the development of FOGTEC water mist goes back a long way... Kamat and Water Mist Lechler and Water Mist FOGTEC Fire Protection
KAMAT was founded in 1974 as a wholly owned subsidiary of F.E. Myers Bro. Co., Ashland, Ohio, USA. The company has been involved in pump and spray technology for over 175 years. |
||||||||||||
Mist nozzle (1938) |
"Fog nozzles" (water mist nozzles) and "Spray guns" (spray branch pipes) were already being produced in 1938, and were used among other things for fire fighting.![]() Mist nozzle(1870) |




![]() Fighting against Fire - Gas - Smoke - Dust tried and tested ![]() Extinguishing of fuel fires |
To extinguish fuel, oil and powder fires, chemical extinguishing is not necessarily needed, since extinguishing with water mist can also produce secure and successful results. In this case the water mist is immediately vaporised above the seat of the fire and the access of oxygen for combustion is greatly reduced or completely prevented. When water mist is applied to fuel and oil fires, there is no danger of further fire spread by the water which has been added to the floating oil. The finely divided water droplets produce an intensive cooling effect, which together with the extinguishing effect offers protection from the strong heat. |

The atomisation of water in the fire fighting business has itself been a well known fact for a very long time. Decades ago, Lechler nozzles were already being used for this purpose. However, this extinguishing procedure has only become widespread in the last few years, above all because of the favourable experience of foreign entities. As opposed to full streams, the following stands out especially: 1. Lower water damage, since the extinguishing water is mostly evaporated. 2. Fast extinguishment, since larger amounts of heat are removed in a shorter time. 3. Possibility of fighting oil and fuel fires. 4. Reduced explosion risk in the case of powder fires. 5. No risk in the case of electrical fires, since the spray discharge works practically like an insulator. |
As well as a wide range of standard and special nozzles, special fire protection nozzles such as mist nozzles were always offered, too.![]() Abstract of Lechler nozzles brochure, 1980 |



![]() |
FOGTEC Brandschutz GmbH & Co. KG |
![]() |
![]() | ![]() |
etnFIT - www.etnfit.net |
FOGTEC in Architectural Atlas...